thanks mohd. but my ndt contractor do not have Phase array. can u please suggest if we can scan it by angle probe ? and how ?
-- i m attaching figure for your reference.
On Fri, Jan 4, 2013 at 12:54 PM, mohd <mohd52100@gmail.com> wrote:
dear,
You can do PAUT instead of conventional or manual UT.
Regards,
Mohd.
--
On Jan 3, 1:19 pm, Samun Bhatia <samunbha...@gmail.com> wrote:
> dear all,
>
> we need to carry out UT on anchor flange of pipeline as per drawing.
>
> in the weld neck portion due to the taper profile we are not getting any
> echo while using TR & straight proble.
>
> so in this neck portion what is the method of UT ? do we have to use angle
> probe ?
>
> please reply in detail.
>
> regards,
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments: