Thursday, November 29, 2012

[MW:16075] Consumable for SA 387 GR-12.CL2 materials

Dear all,


I have a repair work on SA 387 GR-12.CL2 (75mm thick) materials, I tried with E8018-B2,but I didn't get good result. so can u give me suggestion which consumable is give good fusion and penetration for the above materials.


Thanks to all,


Regards,

M.Sudalai

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...