Tuesday, November 27, 2012

[MW:16046] RE: welding with EL8

Hi Kiran,
 
For SAW the wire flux classification is important than filler metal alone. Sec-IX,QW-404.9 addresses this issue.
 
A change from EH14 (1.8% Mn) to EL8( less than 1% Mn) would cause significant reduction in weld metal mechanical properties.
 
Hence this change may not be allowed unless a new PQR is qualified.
 
Thanks.
 
 

Pradip Goswami,P.Eng.IWE

Welding & Metallurgical Specialist

Ontario, Canada.

Email-pgoswami@sympatico.ca,

pgoswami@quickclic.net

 


From: kiran kumar [mailto:chvvn.kirankumar@gmail.com]
Sent: Monday, November 26, 2012 3:54 AM
To: pgoswami@sympatico.ca; pgoswami@quickclic.net
Cc: materials-welding@googlegroups.com
Subject: welding with EL8

Dear Sir
 
Can we weld with Filler wire  EL8 with supporting PQR  EH 14 Filler wire (having same F no:6)
 Material IS 2062
 Construction code -BPVC Section IX
 Process-SAW Process.
 
Thanking you
 
CH.V.V.N.KIRANKUMAR
 
+91 7898905072
 
 

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...