Saturday, September 15, 2012

Re: [MW:15313] PWHT holding temp exceed by 10 deg out of specified limit

No problem if you are below the lower transformation temp.
Best regards
Dr Georgios Dilintas
Authorized Nuclear Inspector
Authorized Inspector Supervisor
HBS Regional Technical Manager


  From: c sridhar [sridhar305@yahoo.com]
  Sent: 13/09/2012 19:25 ZE8
  To: "materials-welding@googlegroups.com" <materials-welding@googlegroups.com>
  Subject: Re: [MW:15303] PWHT holding temp exceed by 10 deg out of specified limit


Mr. Mohd. Sadique Sheikh,

SR temperature  for Carbon steel is 600 0C ± 20 0 for materials having carbon content up to 0.25 % and it is  620 0C ± 20 0for materials having carbon content beyond 0.35 %. It is followed  by BS /EN also.
 
Hence an additional 10 0 C in your case should not be a problem as long as your holding temp. is 2 hrs. for 50mm thick.
 
Sridhar.


From: Sadique Sheikh <sadiq.mech@gmail.com>
To: materials-welding@googlegroups.com
Sent: Thursday, 13 September 2012 11:02 AM
Subject: [MW:15295] PWHT holding temp exceed by 10 deg out of specified limit

Dear ALL,
While reviewing PWHT chart, I found that for IS 2062 E250 B, 50mm butt joints holding temp found exceed by 10degree (Required 590 deg +- 10 deg and observed 610 deg).
My question is 1) Is it acceptable?
2) what will be the effect on joints by exceeding 10 deg temp out of specified limit?
3) Does code permit to do PWHT again on same joints in specified limit of temp?

Thanks & regards,

Mohd. Sadique Sheikh

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
NOTICE: This message contains information which is confidential and the copyright of our company or a third party. If you are not the intended recipient of this message please delete it and destroy all copies. If you
are the intended recipient of this message you should not disclose or distribute this message to third parties without the consent of our company. Our company does not represent, warrant and/or guarantee that the integrity of this message has been maintained nor that the communication is free of virus, interception or interference. The liability of our company is limited by our General Conditions of Services.
Nota : Ce message contient des informations confidentielles propriété de notre société et/ou d'un tiers. Si vous n'êtes pas parmi les destinataires désignés de ce message, merci de l'effacer ainsi que toutes ses copies. Si vous êtes parmi les destinataires désignés de ce message, prière de ne pas le divulguer ni de le transmettre à des tiers sans l'accord de notre société. Notre société ne peut garantir que l'intégrité de ce message a été préservée ni que la présente communication est sans virus, interception ou interférence. La responsabilité de notre société est limitée par nos Conditions Générales de Services.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...