Thursday, September 13, 2012

RE: [MW:15294] Welder Qualification Range for CS to alloy with same dia and thickness?

Dear Chawre ,

Pls 1st read sec xi. Because for welder F number is essential variable and ER 70 S-6  and er 80sb8 / e7018 and e 80108b8 F number same as per section ix so he can weld.

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of ROHIT CHAWRE
Sent: 12 September 2012 23:30
To: materials-welding@googlegroups.com
Subject: RE: [MW:15288] Welder Qualification Range for CS to alloy with same dia and thickness?

 

dear sir,

 

as per my knowledge, welder is not permit to weld ER80SB8 & e8018B8, and is not qualified as per F.no. and is qualified as per material, welder can weld to lower and equal to material as he qualified and higher.

 

thanks n regards

 

rohit chawre


Date: Wed, 12 Sep 2012 15:41:36 +0300
Subject: [MW:15280] Welder Qualification Range for CS to alloy with same dia and thickness?
From: biplab.mech@googlemail.com
To: materials-welding@googlegroups.com

Dear Experts,

 

1 welder is qualified with ASTM A 106 Gr. B with ER70S-6 (Root & 2nd Pass) & E7018(Fill & Cap) with a diameter range of 2 7/8 and above

If thickness and dia of pipe remain same, can he weld on ASTM A 335 Gr. P-9 with ER80s B8 & E 8018 B8.

Construction Code Sec-IX, 2010.

--
Thanks & Regards
Biplab Pal
Mechanical Inspector (PMT)
E-mail:   biplab.mech@gmail.com
 
Information in this email and any attachments is confidential and intended solely for the use of the individual(s) to whom it is addressed or otherwise directed. Please note that any views or opinions presented in this email are solely those of the author and do not necessarily represent those of the Company. Finally, the recipient should check this email and any attachments for the presence of viruses. Myself accepts no liability for any damage caused by any virus transmitted by this email.
 


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...