Hi I think you are seeing hardfacing for first time. Any hardfacing welding will give "stress relief checks or cracks" and are acceptable. You cant avoid them. Only care you should take is that these cracks should not propagate to the base metal and to avoid this a buffer layer is used before hardfacing. Regards Prem Nautiyal
--- On Sat, 9/8/12, Bhupendrasinh Gohil <bbgohil2009@gmail.com> wrote:
From: Bhupendrasinh Gohil <bbgohil2009@gmail.com> Subject: [MW:15244] Hard facing on Hammer IS;276 Mn steel Gr.III Reg. To: materials-welding@googlegroups.com Date: Saturday, September 8, 2012, 11:36 AM
As per Client Requirement Hard facing is Required on the Hammer Mn steel Gr.III and Hardness should be maintain 400 to 500BHN.10mm thk Hardfacing is required on four side Now are doing Hardfacing on the Hammer. First we are making Buffer layer with FCAW process and than we are used GMAT-3200 Electrode for Hard facing. But problem is that after welding Hard Facing are found crack at so many place.
So kindly Give us your Valuable feedback to resolve our matter.
-- Regards,
Bhupendrasinh Gohil MSEL BARODA GUJARAT (Mob.)09687322281 Araise and awake untill u reach the goal.....
-- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
| |
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/ http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments: