Re: [MW:15233] ASME Sec VIII Div.1 UCS-79 clarification

For P No.1 Gr.No.1 & 2 materials, If the nominal thickness is


above 16 mm & fiber el. is more than 5% – Then only SR is mandatory.

In your case, nominal thickness is 16 mm so fiber el. is allowed up to 40% –


Also, Calculate fiber el. from code formula & check for other conditions


mentioned in UCS-79, then only you will come to conclusion.




On Wed, Sep 5, 2012 at 10:44 PM, prem nautiyal <prem_nautiyal26@yahoo.com> wrote:
Hi friends
 
A vessel is being fabricated as per ASME Sec VIII Div.1.
MOC is SA 516 Gr.70
The 2:1 ellipsoidal Dish end nominal thickness is 16mm / min thk 14mm. There is no PWHT and Impact test requirements in the vessel.
I would like to know whether this 16mm thk dishend requires stress relieving or not as per UCS-79.
Vendor has offered dish ends without SR. Is it acceptable?
Nothing is mentioned in client specs and drawing about D/E SR.
 
Regards
 
Prem Nautiyal
 
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...