[MW:15299] Re: Welder Qualification Range for CS to alloy with same dia and thickness?

Yes He can weld. In addition to F no and P.No, Gas backing also need to be considered. only deletion of backing is essential variable

On Wednesday, September 12, 2012 6:11:36 PM UTC+5:30, Biplab Pal wrote:
Dear Experts,
 
1 welder is qualified with ASTM A 106 Gr. B with ER70S-6 (Root & 2nd Pass) & E7018(Fill & Cap) with a diameter range of 2 7/8 and above
If thickness and dia of pipe remain same, can he weld on ASTM A 335 Gr. P-9 with ER80s B8 & E 8018 B8.
Construction Code Sec-IX, 2010.

--
Thanks & Regards
Biplab Pal
Mechanical Inspector (PMT)
E-mail:   bipla...@gmail.com
 
Information in this email and any attachments is confidential and intended solely for the use of the individual(s) to whom it is addressed or otherwise directed. Please note that any views or opinions presented in this email are solely those of the author and do not necessarily represent those of the Company. Finally, the recipient should check this email and any attachments for the presence of viruses. Myself accepts no liability for any damage caused by any virus transmitted by this email.
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...