Wednesday, September 12, 2012

[MW:15283] RE: 15280] Welder Qualification Range for CS to alloy with same dia and thickness?

yes

 

John A. Henning

Welding & Materials

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Biplab Pal
Sent: Wednesday, September 12, 2012 7:42 AM
To: materials-welding
Subject: [MW:15280] Welder Qualification Range for CS to alloy with same dia and thickness?

 

Dear Experts,

 

1 welder is qualified with ASTM A 106 Gr. B with ER70S-6 (Root & 2nd Pass) & E7018(Fill & Cap) with a diameter range of 2 7/8 and above

If thickness and dia of pipe remain same, can he weld on ASTM A 335 Gr. P-9 with ER80s B8 & E 8018 B8.

Construction Code Sec-IX, 2010.

--
Thanks & Regards
Biplab Pal
Mechanical Inspector (PMT)
E-mail:   biplab.mech@gmail.com
 
Information in this email and any attachments is confidential and intended solely for the use of the individual(s) to whom it is addressed or otherwise directed. Please note that any views or opinions presented in this email are solely those of the author and do not necessarily represent those of the Company. Finally, the recipient should check this email and any attachments for the presence of viruses. Myself accepts no liability for any damage caused by any virus transmitted by this email.
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 


______________________________________________________________________
The information in this email is confidential, and is intended solely for the addressee(s). If you are not the intended recipient of this email please let us know by reply and then delete it from your system; you should not copy this message or disclose its contents to anyone. The internet can not guarantee the integrity of this message. HAMON (and its subsidiaries) shall (will) not therefore be liable for the message if modified.
______________________________________________________________________

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...