Tuesday, July 31, 2012

Re: [MW:14994] Which Electrode/Filler wire we should use for 12Cr1MoV ?

Dear friend,

In 12Cr1MoV,the chromium content is only 0.9 to 1.2%. So we can use E8018-B2. In my 600MW chinese boiler all crown plates(Pr.parts support) are fabricated in 12Cr1MoV. Here we use only E8018 as per Chinese instruction.

Regards
Jubair

On Jul 31, 2012 9:58 AM, "Parveen Kumar Nakwal" <pknakwal@gmail.com> wrote:
Dear Experts,
 
In Thermal Power we have material of Strape plate is 15CrMo & we are using E8018B3,
 
Now New material 12Cr1MoV is coming for structure & piping work. Can we use ER 90SB3 + E9018 B3 ?which electrode & filler wire we should use as per standard.
 
If Not kindly suggest me Which Electore & filler wire should we use, as per the standards.
 
Waiting for Reply.
 
Regards.
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...