Re: [MW:14884] Presser test by OIL instaed of Water

As per ASME B31.3, Para 345.4.1, the test fluid for hydro static test pressure test should be water.
Pressure should be 1.5 times maximum pressure if you are doing hydro static pressure test is to be done and equal to maximum operating if hydro static leak test is to be done. The equivalent pressure of oil for water can be calculated by pressure=density x 9.81 m/s2 x height.
Make sure to take all the test water out of line and dry it completely to prevent it from mixing with oil. You will have to rinse it with oil several times.

On Mon, Jul 16, 2012 at 6:06 PM, Ramesh Barot <rameshnbarot@yahoo.com> wrote:
Dear All experts,
 
 
I want to know that can we do presser test by oil instead of water? If yes then let me know the testing presser. Please give some technical reference also.
 
Line detail is mention under:
 
Line size:73 mm X 10 thk.
 
Length:45 mtr
 
Material:SS 304L
 
Max. Working presser:262 bar
 
Oil will be used in operation: ISO grade VG 100
 
The line is for stracker Reclaimer for your information.
 
Waiting for your valuable inputs in this regards.
 
 
 
Thanks,
With Best Regards,
Ramesh Barot

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...