Dear Experts,
                 Can you please share your experience with welding of 4145H.
The problem is as follows:
Base metal UTS = 157ksi
Client spec advises = PWHT @ 560°C

Now, the tensile achieved was only 110ksi
Bend test failed
Macro specimen shows high amount of martensite in the cap side.
CVN @ room temperature = 40Joules

regards,
Harish.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34832] Inquiry about Single Bevel with Back Grinding

Dear Uday, As per your question that one is called with backing only,Simple both side you are welding it is backing with strip or without st...