Sunday, July 22, 2012

[MW:14925] Repair of cladding plate as per SA 264

Dear Expert
please advice-----
Recently we received some explosion bonded clad plate of SA516 gr 70 + SA 240 Tp 316L.
During explosion bonding plate having unbonded area.
As per SA 264 cl No 13.3.3 says that no single unbonded area exceeding 58cm2 with total unbonded area not to exceed 5% of the total cladded surface area.
Does it mean that above 58cm2 unbonded area are not acceptable or above 58cm2 unbonded area repairable upto 5% of total cladded surface area.

Thanks and Regards

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...