Re: [MW:14317] Rust on SS welded joints

Dear,sir
 
  If any spray coating came near this welds- if so does the coating has any zinc or check the chemical composition of the coating.
(usually painting activities follow welding or if any near by C.S structure that were painted ).
--- On Sat, 5/19/12, samuvel masilamani <samuvel.masilamani@gmail.com> wrote:

From: samuvel masilamani <samuvel.masilamani@gmail.com>
Subject: [MW:14310] Rust on SS welded joints
To: materials-welding@googlegroups.com
Date: Saturday, May 19, 2012, 4:57 AM

Dear Experts,
 
we are facing a problem in SS welded joints. most of the joints are found rusted ( layer of rust) after 2 months duration. we checked for the wrong usage of grinding discs,power brush. but everything was found ok.Then we checked PMI, then ferrite test as requested by the client and the results were positive.The pipe material is TP316L, the filler wire usedis ER316L, Electrode E316L-15
 
we proposed the Pickling & passivation as the only solution ,but client is still not satisfied.Is there any other possiblity for the rust formation? Is the redrying temperature& time have any effect on the chemical composition change?
 
kindly clarrify
 
Regards,
Sam 
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...