Wednesday, May 16, 2012

Re: [MW:14285] RT Source Side/Film Side

Gents,

Correct, IQI(s) is (are) required to be placed on source side with given RT set up conditions to verify detectability and then sensitivity of near surface indications, as they are impaired due to increased OFD.

Alternatively, indications within the test object have a better chance of detectability / sensitivity due to decreased OFD.

Since it is not always possible to place IQI on source side, it will be appropriate if technique shots are prepared with IQI on film side & then on source side to compare results for accountability.

Best regards,

Shashank Vagal

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...