Sunday, January 15, 2012

[MW:13478] Additional information into a PQR

Dear All,

We have a PQR in which we did all the mechanical testing as per the
requirement of Sec IX.We would like to add some additional hardness
and impact test result to the same PQR.I have referred the code Para.
QW-200.2 which states that

"additional information can be incorporated into a PQR at a later
date provided the information is substantiated as having been of the
original qualification condition by lab record or similar data"

Can anyone tell me what are the documents to be added to the original
PQR to satisfy the code requirement.


Rins.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...