Hi Jignesh,
 
Section 7 of this standard,specifies  testing requirements  at elevated temperature , so as simulate the worst case conditions. the The default testing temperature is 24 DegC (75 DegF).For  elevated temperature testing the H2S partial pressure should be 100Kpa (14.5psi) or more.
 
As far as testing media (i.e NACE solution A,B,C,D), duration of the test(720 hrs or less) there's is no provision for concession in the NACE standard.

Clause 7.6.4.1.3 addresses the relationship between H2S partial pressure and mole fraction. As par the following equation one may alter the mole fraction to  maintain the required partial pressure.

The severity of  SSC  testing will get altered with the change of temperature and the partial pressure of H2S. If the pressure is reduced the test gets less severe.The issue of SSC is very delicate ,thought provoking. NACE definitely have dedicated guidelines as EFC in Europe.
 
The attached article from Sandvik's website,will provide some exaplanation on this issue.
 
Thanks.
 
Pradip Goswami,P.Eng.IWE
Welding & Metallurgical Specialist & Consultant
Ontario,Canada.
Email-pgoswami@sympatico.ca,

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Desai Jignesh (Mumbai - Piping)
Sent: Saturday, January 14, 2012 12:15 AM
To: materials-welding@googlegroups.com
Cc: pgoswami@quickclic.net; pgoswami@sympatico.ca
Subject: FW: FW: [MW:13476] RE: 13463] SSCC testing

NACE TM0177 testing at high temperature.
 
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of pgoswami
Sent:
14 January 2012 09:51
To:
materials-welding@googlegroups.com
Subject:
[MW:13475] RE: 13463] SSCC testing

 
Hello Jignesh,
 
What's the standard to be followed for SSCC testing.
 
Appreciate your reply.
 
Thanks.
 
Pradip Goswami,P.Eng.IWE
Welding & Metallurgical Specialist & Consultant
Ontario,Canada.
Email-pgoswami@sympatico.ca,
pgoswami@quickclic.net
 


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Desai Jignesh (Mumbai - Piping)
Sent:
Thursday, January 12, 2012 10:19 PM
To:
materials-welding@googlegroups.com
Subject:
[MW:13463] SSCC testing

Hi,
For sulphide stress corrosion cracking of any material at high temp and 90 bar pressure if 0.005 mole % H2S is required, is the test same if pressure is reduced to 60 bar and mole% H2S is increased to obtain same partial pressure.   i.e, if we increase mole % H2S and decrease total pressure, is the test condition remain same or alter?
Regds/Jignesh
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



Disclaimer :This email and any files transmitted with it are intended solely for the use of the addressee(s) only and may contain confidential and/or privileged information. If you are not the addressee, then this message is not intended for you and be advised that you have received this email in error and that any use , dissemination , forwarding, printing or copying of this email is strictly prohibited. In such case please notify the sender and delete this email and any attachments with it from your system immediately.Receipt of this email by you shall not give rise to any liability on the part of Larsen & Toubro Limited


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...