Sunday, January 8, 2012

[MW:13436] G 28 test for Inconel 625 alloy

Dear All,

Base material: SB 444 UNS NO 6625 Gr. 1 ( 1" x 2.77 mm)
Filler wire : ER NICRMO3
PREHEAT: 31 C
INTERPASS TEMP. 105 C
HEAT INPUT: 0.877, 0.767 J for Root and cap PASS

We have carried our G 28 test, but the rate of Corroion is with in
acceptable limit ( 0.05 mm / month)., but at in Micro at X 50 revealed
preferential attack boundaries. Client is not accepting. We have
done twise this PQR, both times, same issue.

Please give your valuable suggestions

Regards

Venkat

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34874] ASME IX, groove weld during WQT limits for Fillet Weld production

Hi David,  There are two points in WQT. 1. Thickness of Base Metal -T 2. Thickness of Weld Metal -t When you use a combination of two proces...