[MW:13380] RE: 13373] Failure Of Root bend test of Welding (CS to SS)

Hi

 

The possibilities could be a weld defect present in the weld metal at root side. Did you check visual and RT. However the type and location of failure is not stated in your query.

 

I wonder for the selection of Filler wire selected for this combination. Usually ER 309L Mo-16/17 is used for this combination. Any background available for this?

BR

M.Vijayan

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of HAREESH K V
Sent: Saturday, December 31, 2011 8:05 AM
To: materials-welding@googlegroups.com
Subject: [MW:13373] Failure Of Root bend test of Welding (CS to SS)

 

Dear Sir,

 

Advance happy new year to all.

 

I have done a PQR(As per ASME Sec ix) of 6", Sa106 GrB to Sa 312 TP 316L. One of the root bend of the same failed.

 

Consumable used: ErNiCr-3. 

 

Tesile strength T1=507 and T2=514MPa(Min Rqd 415MPa);

 

Hardness:

Sa106 Gr B side p.metal: 160,151,147

Sa106 Gr B side HAZ:160,156,156

Weld: 193,170,165

Sa312 TP316L P.metal: 175, 175,181

Sa312 TP316L HAZ: 165,151,151

Face bends are satisfactory.

 

One root bend satisfactory.

 

Please give me the possible reasons and the precautions on further doing the PQR.

 

Regards,

 

Hareesh K V

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



This communication and any files transmitted with it are confidential and may also be privileged. It is for the exclusive use of the intended recipient(s). If you are not the intended recipient or the person responsible for delivering it to the intended recipient(s), please note that any form of distribution, copying or use of this communication or information contained in it is strictly prohibited and may be unlawful. If you have received this communication in error please return it to the sender, and delete the material from any computer. We reserve the right to monitor email communications through normal internal and external networks. We believe but not warrant that the email and the attachments are virus free. The statement and opinions expressed in this communication are those of the writer and do not necessarily represent those of Madina Group, whose registered office address is

P.O. Box 20459, Doha, Qatar.
Tel. +974 44600818
Fax. +974 44603143

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...