There is on structurel in overhead position..MAterial is S 460 N (En
10025 - 3)...Electrode is E 8018-G. But the shrinkage was happen from
the both sides. Over head so Single V only groove taken. Preheat is
110 deg Cel...C clamp also provided to arrest distortion. Any body
give the advice to clear in this contraction....There is no post
heating provided and PWHT. Heat input also not more than 2.5 KJ max.
Thanks in advance
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.