YES.
As per SEC IX, any combination of P1, G1 materials can be welded in any combination to P2, G2, provided Impact test requirements are fulfilled.
Nandesh
From: Madhusudan Rout <madhusudan.rout@gmail.com>
To: materials-welding@googlegroups.com
Sent: Sunday, 13 November 2011 4:37 PM
Subject: Re: [MW:12964] Supplementary essential variable - Group number As per section IX
Yes u can use As per SEC-9. QW-420, base metal grouping, 2010 edition.
-- On Sat, Nov 12, 2011 at 9:14 PM, Vijay Katkar <katkar.vijay22@gmail.com> wrote:
Dear All,--
please sheared your valuable experience for following situation,
I have PQR with P No-1 Gr No-2 to P No1 Gr 1 combination with impact testing. Can i use following combination with same PQR For impact application.
1) P No-1 Gr No-2 to P No1 Gr 2
2) P No-1 Gr No-1 to P No1 Gr 1
3) P No-1 Gr No-2 to P No1 Gr 1
If above combination's are possible please provide code reference of ASME section IX or ASME section VIII.
Regards
Vijay Katkar
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
Comments