if I understood correctly, the nozzle pad is intrfering with weld seam ,is it correct?
On Thu, Nov 3, 2011 at 5:21 PM, Jignesh Desai <jignesh.desai.met@gmail.com> wrote:
Can some body give opinion on below case of closer welds.How can we accept above situation with resepct to any technical justification (PTC etc...)!Material - P. No. 5A - (SA 387 Gr 22 )Service - HydorgenThickness - 45 mmDesign code ASME Sec VIII Div I & API 934 A--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.