Friday, October 14, 2011

Re: [MW:12673] monel welding on wcb

sir,

you can use a welding process having least dilution. this is very tricky welding in which you need to take care of dilution else you will be land up in cracks after PWHT. Most of the litratures are suggesting NiCu1 for barrier layer (to take care of chemistry due to dilution) and subsequent layer with NiCu7. alternately you can also use Nicu7 for barrier and subsequent layers. SMAW and P-GMAW both can give satisfactory results but special care for welding and good welder skill is required.

Regards,
VJ

On Fri, Oct 14, 2011 at 10:28 AM, n.gupta <n.gupta@nsslindia.com> wrote:

Dear Experts,

 

                I want  monel overlay on A105 Ring Dia 102 mm width 5mm  and thickness 22 mm.

 

Which Process and Welding Electrode Should I use ??? Please Suggest.

 

 

 

Regards

 

Narayan Gupta

 

--------------------------------------- NECO Group Of Industries, Nagpur, India   !-- Virus-Free Mail Using AntiVirus for PostMaster Enterprise & QuickHeal Engine --!

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...