Sunday, September 25, 2011

Re: [MW:12517] welder qualification - aws d1.1



Dear Sir,

No it is not given in AWS D1.1. But for larger Dia such as 30" like may be welded by 2 welders for PQR , welder qualification  etc subject to half the portion shall be welded by one welder alone. 

Actually while qualifying welder he has to weld minimum 12" minimum then only we can judge their ability to weld as in the case of plate . same way for pipe this minimum length may be adopted and it is accepted too.



Thanking You,

Honesty is the best Policy

With Warm Regards,

Muthu Barathi P
Mobile No:00962788269821 (Jordan)
00962775401951


From: daniel iordache <daniel.iordache@gmail.com>
Sent: Sun, 25 Sep 2011 12:53:11
To: materials-welding@googlegroups.com
Subject: [MW:12514] welder qualification - aws d1.1
Dear experts,

Anyone can indicate me where AWS D1.1 has indicate that for Welder Qualification test for 6G pipe  8"diameter  x 1" thickness  ...ca be used one sample for 2 welders ( each welder - one side - half of pipe)????

Thanks 

--
Daniel Iordache
Bureau Veritas - Angola
South Angola - Projects coordinator
Mechanical& Welding Surveyor
Mobile Ao: +244921544583
Mobile Ro:   +40721731728
E-Mail:daniel.iordache@ao.bureauveritas.com
       daniel.iordache@gmail.com
          

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


Treat yourself at a restaurant, spa, resort and much more with Rediff Deal ho jaye!

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...