Saturday, September 24, 2011

Re: [MW:12513] PWHT temperature below tempering temperature

did you check the heat treatment condition of your A106 Gr B pipe? in
case it is supplied as either N&T or Q&T, what is the tempering
tempering temperature on MTC? your PWHT temperature shall be at least
20 °C less than the tempering temperature of the pipe and not 20 °C
less than max PWHT temp given in code. if the pipe is not tempered,
this clause will not be applicable.

for. e.g tempering temp as given in MTC is 650 °C, then your max PWHT
temp will be 630 °C

On Sat, Sep 24, 2011 at 3:06 PM, M S <striarc@yahoo.com> wrote:
> Experts,
> Pls advise, Client spec as below for PWHT
> "For quenched/normalized and tempered steels, the PWHT temperature shall be
> such as to avoid an unacceptable decrease of mechanical properties of the
> parent material; PWHT temperature shall be maintained at least 20 degC below
> the tempering temperature."
> And Client recommend to use PWHT temperature is 593–629 deg C, but as per
> B31.3 it is 593–649 degC. Client reduced 20 degC in the max. temperature
> range(649-20=629)
>
> Material: CS(A106-B > 20mm)
> Is it correct as per spec?
> Regards,
> Stri
>

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...