Wednesday, September 14, 2011

Re: [MW:12449] Requirement of Solution Annealing for SS DIshed head after forming

Dear Mr. Asad,

I like to share my views on the topic with respect to the various applicable code.

1.0 ASME Section VIII  Div. 1 -    Since the material is SA 240 316L,(and assumed that is being cold worked)  , requirements of post fabrication heat treatment due to straining as per
       UHA- 44 will not be applicable and therefore  solution annealing is not required. Please note that any of- L Grades" is  not included in table UHA- 44.

2.0  Considering Sour Services-----

       NACE MR 0103 - Austenitic stainless steel shall be supplied with 22 HRC hardness max. in solution annealed and quenched or sol. annealed and thermally stabilized conditions.
       As per this clause thermal treatment is not required (if  fiber elongation exceeds 5 %), which is case for carbon and low alloy steel as per clause no. 2.1.7 of NACE MR 0103.

However, considering good practice, ensure hardness of formed dished end below 22 HRC.

With Best Regards,

Jignesh R Rana
Manager - Materials Technology, QA/QC & Standards

Linde Engineering India Pvt. Ltd.
'Linde House'
Opp: VUDA Office, VIP Road, Karelibaug,Vadodara - 390018, India.
Tel.: +91 265 3056789, Fax: +91 265 2335213 , Mobile:  +91 90999 86019
jignesh.rana@linde-le.com,
www.linde-india.com

This e-mail is confidential. If you are not the intended recipient, please notify us immediately. You should not disclose its contents to any other person nor use it for any purposes.






From:        asad azmi <azmiasadayub@gmail.com>
To:        materials-welding@googlegroups.com
Date:        13-09-11 16:55
Subject:        [MW:12442] Requirement of Solution Annealing for SS DIshed head after forming
Sent by:        materials-welding@googlegroups.com




Dear All,
 
Greetings.
 
SS Vessel is being fabricated as per construction code - ASME SEC VIII DIV 1
 
SERVICE : SOUR Service
 
Material of Construction  for Dished Head - SA 240 316L, 20 mm Thickness.
 
I  believe stresses will be  induced in the material  during forming and as a result , Sulfide Stress Cracking (SSC) failure may occur during operation.
 
Whether Solution Annealing of SS Dished Head is required after forming?
 
Please give reference of any International Standard.
 
Thanks & Regards
 
Asad Azmi

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...