Tuesday, September 13, 2011

[MW:12444] Computer Radiography system for RT of welds in line with ASME code

We are planning to go for film less radiography by shifting to Computer Radiography.

Our application involves steel welds of thickness ranging from 6mm to 60mm.

The sources what we are intending to use are X ray machine of 300Kv, Selenium 75, Iridium 192 and Cobalt 60.

I have studied the technical spec.s of various available CR systems of brands GE, VMI, Kodak, Durr, QSA global and CIT.

Could any one share their experience with any of the above systems in Computer Radiography and suggest which is best among them with respect to hard ware , Software and after sales services.

Regards,

Raghavendra
AGM - NDE
NDE Level III
HED - L&T Ltd.
Hazira - Surat
Gujarat , India.


Larsen & Toubro Limited
www.larsentoubro.com

This Email may contain confidential or privileged information for the intended recipient (s) If you are not the intended recipient, please do not use or disseminate the information, notify the sender and delete it from your system.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...