[MW:12393] RE: 12384] acceptable criteria for ferrite percentage in DSS weld metal

Dear Sir,

 

Ferrite percentage acceptable for weld metal and HAZ is depending on the applicable specification; 35 – 70 % is often used but please take a look at the applicable specification which should specify such.

For piping and vessels the base material specification will give requirements for acceptance criteria of material, but in most cases requirement for ferrite content is not mentioned. Normally this should be between 40 – 60 % as a general accepted value. In cases where base material specification doesn’t specify any requirement for ferrite content this should also be specified by your client as a supplement requirement in his project specification. But normally when material is produced according to the base material specification the ferrite content will always be acceptable (is determined by chemical composition and final heat treatment).

 

Met vriendelijke groeten / Best Regards

 

Herman Pieper

 

Pieper Quality Support & Inspection

Phone: +31 (0)521 380083

Fax:     +31 (0)84 7539225

Cell:     +31 (0)6 51691215

www.pieper-qsi.nl

 

Van: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] Namens sudhakar kuppuswamy
Verzonden: vrijdag 9 september 2011 7:08
Aan: materials-welding@googlegroups.com
Onderwerp: [MW:12384] acceptable criteria for ferrite percentage in DSS weld metal

 


what is the acceptable criteria for ferrite percentage in DSS weld metal...? 
up to how much % ferrite we can accept the weld metal...? 
what is the reference std for this for piping and pressure vessels.

--
With regards,
Sudhakar.k

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...