Monday, August 22, 2011

Re: [MW:12299] PDR for welder overlay on flanges

ALWAYS BECAUSE IT IS ALSO RELATED WITH THE EQUIPMENT AND IT IS A PRESSURE PART

On 8/22/11, Arunachalam A <arunvani@gmail.com> wrote:
> 1)Yes.
> 2)Yes.
>
> I assume that these flanges are part of nozzles.
> Permanent blind flanges which are part of Vessels shall also be U-part
> stamped if overlayed by welding.( Example: Manway blinds)
>
> Arunachalam
>
> On Fri, Aug 19, 2011 at 8:44 PM, imran khan <imransian@gmail.com> wrote:
>
>> Dear All,
>>
>> we are pressure vessel manfacturer having U - Stamp , we purchase some
>> flanges of carbon steel which are overlayed, But the supplier did not
>> provide PDR
>> my question is ,
>>
>> 1) Is it required?(Section VIII div. 1 addition 2007)
>> 2)Does the flanges should be stamped "U"
>>
>> --
>> *With Best Wishes,*
>>
>> *Imran *
>>
>> * *
>>
>> --
>> To post to this group, send email to materials-welding@googlegroups.com
>> To unsubscribe from this group, send email to
>> materials-welding+unsubscribe@googlegroups.com
>> For more options, visit this group's bolg at
>> http://materials-welding.blogspot.com/
>> The views expressed/exchnaged in this group are members personel views and
>> meant for educational purposes only, Users must take their own decisions
>> w.r.t. applicable code/standard/contract documents.
>>
>
>
>
> --
> Arunachalam.A,
> Abu Dhabi Gas Industries Ltd,
> P.O.Box # 50124
> Abu Dhabi, UAE
> Mobile : +971-50-5257122
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding+unsubscribe@googlegroups.com
> For more options, visit this group's bolg at
> http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...