Sunday, August 7, 2011

Re: [MW:12149] API storage tank settlement tolerance.

Please, go to 7.3.6.5, 7.3.6.6, B2 and B4 standard API 650 
Regards,
jml, Colombia South America

2011/8/6 manoj john <manojacgnr@gmail.com>
Dear All,

I have one storage tank to erect at site as per API 650.  The size of the tank is 54 meter diameter and during water fill up test we have to measure settlement.  Can any body give me information about tank settlement tolerance and in which standard it is specified.

Thanks,
Regards.
Manoj

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire