Dear All,
Material : ASTM A106 Gr. B
Thickness : 12.70 mm
Welding Process : SMAW
Electrodes used as per approved WPS : SFA 5.1, E6010 (Root)+ SFA 5.1, E7018(Fill&Cap)
During through thickness repair, by mistake root pass has been punctured badly(5-8cm in length after complete removal).Unfortunately,now the root gap is almost 10-12 mm wide and it is difficult to weld root again with E6010.In this case what is the better option other than cut and bevel the joint.Is there any problem to build root with GTAW by using ER 70S2 and fill remaining thickness with 7018?
Regards,
Limesh
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
Subscribe to:
Post Comments (Atom)
Re: [MW:34832] Inquiry about Single Bevel with Back Grinding
Dear Uday, As per your question that one is called with backing only,Simple both side you are welding it is backing with strip or without st...
-
Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? ...
-
Definition of buttering from ASME Section IX, QW/QB-492 Definitions: Buttering: the addition of material, by welding, on one or bot...
-
Section I. PRINT READING 3-1. GENERAL a. Drawings . Drawing or sketching is a universal language used to convey all necessary information to...