Tuesday, July 26, 2011

Re: [MW:11934] Conflict of TP-321/TP-304L

Yes you can use the same supporting PQR, just make new WPS as per Sec IX.
 
Regards
 
Prem S Nautiyal

--- On Tue, 7/26/11, pradip kumar sil <pradipsil@gmail.com> wrote:

From: pradip kumar sil <pradipsil@gmail.com>
Subject: [MW:11931] Conflict of TP-321/TP-304L
To: materials-welding@googlegroups.com
Date: Tuesday, July 26, 2011, 11:50 AM

Hi,
I have one wps with established pqr @ ASTM A-312 TP321H with filler ER-347. Can i establish ASTM - A-312 TP-304L with ER-308L with the help of ASTM-A-312 TP 321 PQR. Base metal & filler P no, Fno, SFA no, A,no & GROUP no & other variable are same.
Can i use TP-321 PQR FOR establish of TP-304L.
Waiting for ur valued reply.
Regards
Pradip
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...