Monday, July 25, 2011

RE: [MW:11913] P-11 with purging

Dear Dinesh,

This essential variable QW-408.9 only applicable in deletion of backing gas, not addition.

Best regards,
Kang


Date: Mon, 25 Jul 2011 17:19:38 +0300
Subject: Re: [MW:11910] P-11 with purging
From: som.din@gmail.com
To: materials-welding@googlegroups.com

QW-408.9 For groove welds in P-No. 41 through
P-No. 49 and all welds of P-No. 10I, P-No. 10J,
P-No. 10K, P-No. 51 through P-No. 53, and P-No. 61
through P-No. 62 metals, the deletion of backing gas or a
change in the nominal composition of the backing gas from
an inert gas to a mixture including non-inert gas(es).

IT IS NOT CLEARED THAT FOR P11.

REGARDS

DINESH


On Mon, Jul 25, 2011 at 4:15 PM, Morin, Darcy (Bantrel Management Services) <MorinD@bantrelmanagementservices.com> wrote:
According to ASME IX QW-256, QW-255, the deletion of backing gas is considered an essential variable. But, the addition of backing gas is not an essential variable.  This means that if you add a backing gas, a new WPS is not required by ASME IX. 
 
However, your customer's specification may require a new PQR, with a new set of mechanicals, reflecting the purged condition..


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of pradip kumar sil
Sent: Saturday, July 23, 2011 9:29 AM

To: materials-welding@googlegroups.com
Subject: [MW:11877] P-11 with purging

Hi,
I have one ESTABLISHED  WPS for P-11 which is not purged by argon but as per our client specification purging is required for P-11. Can anybody tell me can i use ESTABLISHED WPS for with purged condition.  For that one, what is the criteria  & where it is written in code.
Regards
Pradip

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
This e-mail and any attachments may contain confidential and
privileged information. If you are not the intended recipient,
please notify the sender immediately by return e-mail, delete
this e-mail and destroy any copies.

Any dissemination or use of this information by a person other
than the intended recipient is unauthorized and may be illegal.


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...