Re: [MW:11906] AWS D1.1 Table 4.6 Clause 1-Change in Group No.

Dear K Babu,

WPS qualified on group II materials can be use on group I and Group II and its combination if all other variables are constant.
As per the CVN @-40, if the values obtained @-40 met the specification requirement @ -20 then the WPS is qualified as you requested. so you need to check the minimum value required @-20 and if the values obtained @ -40 meet the requirement @-20.

Regards,

Rems Okonkwo

On Sun, Jul 24, 2011 at 2:55 PM, K.Babu <kbabupsg@gmail.com> wrote:
Gents,
 
 
WPS is qualified in Group II to Group II, with CVN @-40 deg. cel.,
 
Can we use this WPS , to weld Group II to Group I  combination with requirement of CVN @-20 deg cel.
 
 
Thanks & regards,

K.Babu

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...