Monday, July 25, 2011

Re: [MW:11902] Inconel Overlay Precautionery steps

plz control the ineterpass temperature while doing the overlay.

On Sun, Jul 24, 2011 at 7:17 PM, rinshad abdul rahman <rinshad043@gmail.com> wrote:
Dear Mr. Babu,

By Manual SMAW not at all possible to get 5% Fe at 3 mm from fusion line 
by using 2.4mm dia electrode.There will surely more 6% Fe will be there.
 
 
Regards
 
Rinshad


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...