Thursday, July 21, 2011

Re: [MW:11843] Where we can find Impact testing recorded values @ - 34 C for SA 537 CL 1 Material

you may refer table 4.3 for values (10/15ft-lb, average/individual values for SA537 cl1 plate upto 2" thickness), unless most strignet values are given elsewhere in the contract.

On Wed, Jul 20, 2011 at 10:10 PM, Suresh <bobsuresh24@gmail.com> wrote:
Hiii ,
 
Design Code is API 620 ..
 
Wait for your earlier response
 
Suresh

On Wed, Jul 20, 2011 at 10:08 PM, Raghuram Bathula <raghurambathula@gmail.com> wrote:
What is your design code?


On Wed, Jul 20, 2011 at 8:26 PM, Suresh <bobsuresh24@gmail.com> wrote:
Dear All ,
 
I would like to requesting you that ....We are doing Ammonia Tank erection which is using SA 537 CL 1 material ...
 
Now we are doing PQR for 537 Material @ - 34 C (which has tested by manufacturer ) and as per MDMT .
 
My Question is that here we can find the Impact recorded values for SA 537 CL1 @ - 34 C ...I need which code it was showing ...Client need that copy prior to go for PQR .
 
--
Thanks  & Best Regards,

Suresh

Mobile No: 91-92 92 905 905

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...