Spent caustic is the waste industrial caustic solution, that has become exhausted and no longer useful (spent). It is made of Sodium hydroxide or potassium hydroxide, water and contamination. The common and dangerous contamination is H2S in it.
Various process licensors have technology for effective and environmental disposal of spent caustic and guidelines for material selection as well as for PWHT also.
Refer the pipe class generated for spent caustic line, for PWHT & NDT requirements.
PWHT is dependent on concentration of Caustic and design temp. In normal case, % caustic is < 5.0 % and temp. varies from RT to 130 -140 Deg C.
Since, H2S would contamination; this would fall in category M services as per ASME B 31.3.
With Best Regards,
Jignesh R Rana
Manager - Materials Technology, QA/QC & Standards
Linde Engineering India Pvt. Ltd.
'Linde House'
Opp: VUDA Office, VIP Road, Karelibaug,Vadodara - 390018, India.
Tel.: +91 265 3056789, Fax: +91 265 2335213 , Mobile: +91 90999 86019
jignesh.rana@linde-le.com, www.linde-india.com
This e-mail is confidential. If you are not the intended recipient, please notify us immediately. You should not disclose its contents to any other person nor use it for any purposes.
From: mpk mpk <ranmi2007@gmail.com>
To: materials-welding@googlegroups.com
Date: 18-07-11 10:52
Subject: [MW:11781] PWHT and NDT requirement for SPENT CAUSTIC LINES
Sent by: materials-welding@googlegroups.com
Dear Experts,
We have 2" sch 160 & 4" sch 80 C/S Piping welding ,whether we need to conduct PWHT for these lines or no need , because as per standard CAUSTIC service lines need PWHT. but in our package the service fluid is SPENT CAUSTIC and I want to know what is the required percentage of NDT for these service lines,
Please send suggestion & if any specific documents..
Thank you,
MPK
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/