Monday, July 18, 2011

Re: [MW:11800] FW: hydraulic test pressure of Pipe.

Hi,
For Stainless stell pipes,(Ex.,SA312) please find below the Code Extraction od SA312. It is the option of the manufacturer unless otherwise purchaser specified to do Hydroatatic test.
 

12. Hydrostatic or Nondestructive Electric Test

12.1 Each pipe shall be subjected to the nondestructive

electric test or the hydrostatic test. The type of test to be

used shall be at the option of the manufacturer, unless

otherwise specified in the purchase order.

12.2 The hydrostatic test shall be in accordance with

SpecificationA 999/A 999M, unless specifically exempted

under the provisions of 12.3.

12.3 For pipe whose dimensions equal or exceed NPS

10, the purchaser, with the agreement of the manufacturer,

may waive the hydrostatic test requirement when in lieu

of such test the purchaser performs a system test. Each

length of pipe furnished without the completed manufacturer's

hydrostatic test shall include with the mandatory markings

the letters "NH."

12.4 Nondestructive Electric Test:

Nondestructive electric tests shall be in accordance with

Specification A 999/A 999M.

 

16. Certification

16.1 In addition to the information required by Specification

A 999/A 999M, the certification shall state whether

or not the material was hydrostatically tested. If the material

was nondestructively tested, the certification shall so state

and shall show which standard practice was followed and

what reference discontinuities were used.

 
For Alloy Tubes (Ex.,SA213) Please find below the Code Extraction of SA213
 

10. Hydrostatic or Nondestructive Electric Test

10.1 Each tube shall be subjected to the nondestructive

electric test or the hydrostatic test. The type of test to be

used shall be at the option of the manufacturer, unless

otherwise specified in the purchase order.
 
 
 
Thanks & Regards,
 
 


(Karthik)

Karthikeyan.S
QA/QC Manager
Getabec Energy Co.,Ltd.
379,Moo6,Soi8,Nikhomphatana,
Rayong-21180,
Thailand.
Phone: 0066 38 897035-8 (Off)
Fax: 0066 38 897034
Hand Phone: 0066 892512282


--- On Mon, 7/18/11, subrata das <sdas@pkgroup.org> wrote:

From: subrata das <sdas@pkgroup.org>
Subject: [MW:11794] FW: hydraulic test pressure of Pipe.
To: materials-welding@googlegroups.com
Date: Monday, July 18, 2011, 11:45 AM

Dear Experts

Generally hydraulic test pressure of Carbon Steel pipes are defined by SA-53. But what about the Stainless Steel & Alloy Steel pipes ? Can anyone reply please.  

 

Regards

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...