Thursday, July 14, 2011

Re: [MW:11733] Re: ferrite content in DSS

Dear Prashant,



121.jpg



Regards,

Limesh



On Fri, Jul 8, 2011 at 11:03 PM, mohd.qce <mohd52100@gmail.com> wrote:
Dear prashant,

DSS  havning ferr+aus phase we know that correct.

DSS when we used for our desal project we used to control ferrirte %
in betweeen 30-80%.
becse if ferrite % increse it will impair corrosion resistance
property.

even u hve to control carbon contamination in all phse of
activities.grind while...tools n tackel..maximum protection from
carobon pickup.during welding and fabriction.

i suggest you to read practicle guideline for fabrication of
DSS(thyssen krupp).

regards,
mohd.



On Jul 8, 11:57 am, prashant pansare <prashantpan...@yahoo.co.in>
wrote:
> Dear all,
> why we need to check ferrite content in DSS(base matl) & weld?
> What is the effect if ferrite content increases or decreases?
> Kindly reply.
>  
> Thanx & Regds,
>  
> Prashant

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...