no need to call me sir as I can answer u normally .... Hehehehe I'm also member FYI
Regards,
Kalyan (QA KeppelFELS)
Sent from my iPhone 4G
On 12-Jul-2011, at 10:28 AM, santhosh balan <balansanthosh1983@gmail.com> wrote:
> Dear Sir
>
> We have to do the hydro test on the pipe having Dia 8'' to 20'' and
> the pipe length is 150meter, the system testing pressure required is
> 15 bar. So how can i select pump pressure rating and power, as we have
> buy a new pump.
>
> Regards
> B.santhosh
> ESO Thailand
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
> For more options, visit this group's bolg at http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments: