Monday, July 11, 2011

Re: [MW:11668] unassigned material wps pqr

Dear pankaj

As per my understanding you can not use the WPS PQR for P1 to
unassigned material.
If you have the WPS PQR for P1 and unassigned material then you can
use that with an unassigned mat and the material having the same P
number.

On Sat, Jul 9, 2011 at 10:32 PM, pankaj kolhe <pankaj.kolhe15@gmail.com> wrote:
> HI,
> I have a WPS PQR for IS 2062 gr B to IS 2062 Gr B that is unasigned mat to
> Unassigned mat.
> Also I have a WPS PQR for P1 to P1
> So, my question is can i use above WPS PQR for P1 to Unassined mat. that is
> SA 106 Gr b to IS 2062
> if yes then why?
> if No then why?
>
> Pankaj+
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding+unsubscribe@googlegroups.com
> For more options, visit this group's bolg at
> http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>

--
Regards
Ashish Yadav
Institute For Plasma Research

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...