Sunday, July 10, 2011

Re: [MW:11659] E7018-A1 Electrod

For creep properties, use .0.5mo only,

2011/7/5 Zakaria ghrab <zakaria.ghrab@gmail.com>
Hi All,

  In our boiler project we have to weld socket tube A210 Gr A1,  38 mm diameter , 4 mm thick  to collector P11 material thick , according client WPS we have to weld by E7015-A1.

What's the difference between EXXXX and EXXXX-A1
May E7018 substitue E7015-A1 ?

Kind regards

--
زكرياء غراب
GHRAB Zakaria
مسؤول عن الجودة
QA/QC SENAD
مشروع المحطة الحرارية ـ الوحدة الرابعة
المحمدية ـ المغرب

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...