Friday, July 1, 2011

Re: [MW:11562] Welding by Inconel to P11a material

Dear Maulik,
As per my point of view you can use both the consumables mentioned bu you. As they both gives good impact value in cryogenic temperature range.
It is correct that ENiCrMo6 is the best matching one but there is no problem in using ENiCrMo3.
 
Regards,
Huddar

On Thu, Jun 23, 2011 at 10:37 PM, Maulik H. Thakkar <mlkthakkar2@gmail.com> wrote:
Dear All,

Request you to suggest me the suitable inconel welding electrode
(SMAW) for welding of P11A # P11A base material.

Details: 9% Ni steel, No PWHT, Base Metal Thickness 13 mm. Impact
required 27J min @ -183 degree cen.

As per ASME SEC II-C most suitable consumable is ENiCrMo-6. However
can I use ENiCrMo-3? If yes why & if no why?

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...