Tuesday, July 12, 2011

[MW:11695] Using 10018-G Electrode replacing 9018-G in WB-36 Material with out qualifying PQR.

Dear Friends,

We have a qualified PQR for WB-36 Material using E 9018-G material and
we are using it in site.Now a vendor is supplying us 10018-G which is
more available.

Can I use 10018-G instead of 9018-G without qualifying PQR.I think in
both cases essential varialbles are same....


Also Is there any problem in using 9018-G instead of 10018-G without
qualifying PQR....


Regards,
Jose

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...