Tuesday, July 12, 2011

[MW:11686] Selection of Hydrostatic Pump for Pressure testing

Dear Sir

We have to do the hydro test on the pipe having Dia 8'' to 20'' and
the pipe length is 150meter, the system testing pressure required is
15 bar. So how can i select pump pressure rating and power, as we have
buy a new pump.

Regards
B.santhosh
ESO Thailand

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...