Wednesday, May 25, 2011

Re: [MW:11142] Minimum length of shell

Minimum length of shell= 5 T (T = shell thicknes)
see

ULT-17 WELDED JOINTS




Yours sincerely,

QA/QC Eng.
ibrahim mohamed

Tel

E-mail: eng_hema1900@yahoo.com


--- On Sun, 5/22/11, waman nilesh <wamannp@gmail.com> wrote:

From: waman nilesh <wamannp@gmail.com>
Subject: [MW:11116] Minimum length of shell
To: materials-welding@googlegroups.com, materials-welding@goolegroups.com
Date: Sunday, May 22, 2011, 5:32 PM

I want to know how much minimum length of shell in pressure vessel we can use as ASME VIII division I.

With Regards,
Nilesh

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...