Friday, May 6, 2011

Re: [MW:10978] WQT

You have to inspect the root pass alone to see the weld is free from any discontinuity..
 
msms

On Fri, May 6, 2011 at 3:00 AM, ABHISHEK GHOSH <ghoshabhishekmech@gmail.com> wrote:
During WQT, root runs should be inspected after hotpass only /? or it should be inspected after only root pass.
 
pls advice..

--
ABHISHEK GHOSH
FAHAHEEL, KUWAIT
MOB: (00)965-60303798

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...