Hi,

I assume you are dealing with ASME code, which stear you to Article 4 of ASME Sec v. this only ask to use "Pulse Echo Technique" so basically you can use any of them (UT or PAUT).

However if code being followed is Australian code, it says "

Welds made by GMAW welding should be examined with mechanized ultrasonic testing" so this ask for PAUT only for the specified reason.

 
For Longitudinal welding, it's better to run PAUT which can detect defects in the range of 6.4 to 52mm, a generaic idea, some advancements might have occured.

Section VIII Division 1 UW-11(a) (2) call for full radiography of all butt welded joints with nominal thk exceeding 38mm and welds in nozzles exceeding 29mm wall thk.

Should you have further query, feel free to post.

Regards
Manpreet Singh


On Thu, 05 May 2011 23:08:39 +0530 nam raz <namrazpn@gmail.com> wrote
>
Dear all,
 
Please clarify my below mentioned queries,
 
Can we use  Manual UT or PAUT (PHASE ARRAY ULTRASONIC TESTING) for finding defects in 18" API 5L X65 ,7.2mm thickness pipe.The pipe is longitudnal welded.We have to scan the only on the longitudnal seam.
 
Please confirm,weather the code permits to do UT on this thickness,if any code says please send me the details.
 
Also please clarify,if any code restricts the UT to any thickness limit(MIN/MAX)
 
If anyboby need more details,please ask me...
 
 
Regards,
 
Namzi..
Doha,Qatar
 
 
 
 

--
>To post to this group, send email to materials-welding@googlegroups.com
>To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
>For more options, visit this group's bolg at http://materials-welding.blogspot.com/
>The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
>

Treat yourself at a restaurant, spa, resort and much more with Rediff Deal ho jaye!

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...