Hi,
Construction Code? Let take this as ASME....
First you should have a qualified WPS.
As per Sec.IX,If There is a change in F.No. is an essential variable for WPS.How can you use the F.No.6 WPS to F.No.43?
If you have a qualified WPS for the require P.No.with the F.No.43,then you can proceed for WQT.
What type of fillet weld? (Plate to plate or Pipe to pipe or Plate to Pipe?).

Anyhow for Production assembly Mock ups can be used for WQT(Fillet Weld). Pls.refer QW-181.2.1 - ASME Sec.IX

Thanks & Regards,

(Karthik)

Karthikeyan.S
QA/QC Manager
Getabec Energy Co.,Ltd.
379,Moo6,Soi8,Nikhomphatana,
Rayong-21180,
Thailand.
Phone: 0066 38 897035-8 (Off)
Fax: 0066 38 897034
Hand Phone: 0066 892512282


--- On Thu, 5/5/11, venkat kumar <vsslsrk@gmail.com> wrote:

From: venkat kumar <vsslsrk@gmail.com>
Subject: [MW:10953] Reg:welder qualification
To: materials-welding@googlegroups.com
Date: Thursday, May 5, 2011, 9:54 AM

dear experts,

we have dissimilar materials  (only fillet weld is coming) between P9 to P8,due to lack of material we want to conduct welder test on production joint it self.we have welders qualified in P9 (FNo.6) and P8 (FNo6),
but for now we are using filler wire ERNiCr-3 (F.No43) for dissimilar materials.how we can qualify welder on fillet weld.is there any applicable standard is there?pl let me know.

thanks & regards


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...