Wednesday, May 4, 2011

[MW:10940] Reg: how to select filler wire for dissimilar metals

dear experts,

pl guide me that how to select filler wire according to given material.for instance if material is dissimilar, base material having 9Cr,1Mo,other material SA 351 HK 40,having Cr.23-27,Ni.19-22.one of our expert suggested that ErNiCr-3 as a filler wire.Other than material what characteristics are we have to take in to consideration to select filler wire.
 

thanks & regards


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...